Changing insulation during renovation: how to read a Kingspan offer

At a glance

Selecting Kingspan insulation for a renovation begins with establishing what is actually present in the existing building element, not with the brand name in the offer. In old documentation, the brand is sometimes too general a clue, because Kingspan Therma TR26 and Therma TR27 are boards with a PIR core, while the Kooltherm family uses phenolic foam. The brand alone therefore does not identify the type of insulating material or the function of the layer. During the pre-renovation inspection, the product must be identified by its core, its facing and its intended place of application, especially when the project description gives only Kingspan without a specific family and variant. Only on this basis is the scope of demolition work and the method of preparing the old building element determined.

PIR board seen close up, with a silver facing and a straight light edge

Survey before selection

A new surface does not solve everything: the manufacturer’s name covers various materials, including PIR Therma and phenolic Kooltherm. Demolition and repair work should make it possible to identify unambiguously the material suited to the designed function and method of execution. Before the PIR boards cover the old layers, document the full product name, the core type, the properties document and the place of application in the building.

Removing the cause of the defect

The Therma insulation board is not the same product as a complete sandwich panel with structural facings. The load-bearing function, the fixing and the method of forming the sealed layers must be attributed to the actual solution, not to the insulation alone. Before covering the existing structure, examine the change of insulation product in the section that has separate layers for vapour control and water protection.

The material change must preserve the continuity of the designed water protection and vapour flow before the new construction conceals the places important for assessing the cause of the problem. Adding insulation alone does not close the matter when a similar board colour does not confirm the same conditions of connection to the membrane or flashing. Polyurethane foam in a finished product does not replace repair; first the correct protective arrangement must be maintained regardless of the chosen rigid insulation family. After preparing the location, check again the description of all layers, the perimeter details and the scope of documentation concerning the proposed replacement, instead of basing acceptance on the appearance of the new surface.

In the documentation of an older building, only the general name Kingspan may appear. Before selecting the new insulation, it is worth establishing which product was actually used, because the appearance of the exposed core is not sufficient for unambiguous identification. You should look for markings and documents, and assess the condition of the layers independently. The replacement for the renovated section is selected for the identified task, not for surface similarity alone.

New layer and old cross-section

Therma TR26 has a thermal conductivity of 0.022 W/(m·K), while for Therma TR27 it depends on the thickness. With the limited geometry of the renovated section, compare TR26 and TR27 boards with different thermal conductivities at the same thickness, reading the parameter of the precisely selected variant and calculating the equivalent thermal effect.

Prepare the comparison of Kingspan variants at the same required thermal resistance before limited space forces a change to the designed cross-section. Old documentation may not be sufficient, because attributing a lower thermal conductivity to the whole brand distorts the parameters of the other families. When comparing what new polyurethane boards will deliver, check thermal equivalence at the level of the precisely designated variants in the offer. For measurements of the existing condition, add the thermal conductivity for the selected thickness, the appropriate RD and the consequences of changing the build-up height, and then compare with the planned cross-section.

Connection to the existing structure

Replacing TR26 with TR27 changes the surface to which the covering will be joined: the laminate containing aluminium gives way to a glass fibre facing. During renovation, this difference must be noted at the cross-section of the junction between the new and the retained part. The construction of both surfaces must correspond to the adopted connection of the roof layers.

When replacing a board, check the compatibility of the new facing with the fastening and the covering also at the junction of the new layer with elements retained in the building. On-site fitting can be difficult, because the common PIR core does not allow the product to be swapped without assessing the connections between the layers. Set the sequence of works so as to preserve the function of each junction after the material change proposed during execution. When accepting the section where the new polyurethane insulation ends, assess the type of surface, the permitted method of connection and the geometry of the sides in both compared boards.

Board properties and renovation stages

Reaction to fire concerns the material, while fire resistance concerns the entire building element; these are two separate test results. Compressive stress at 10% deformation is not a design load value. During renovation, when some layers remain, confirm separately the data on the material’s reaction to fire, compressive stress and the fire resistance of the system.

Assign Kingspan parameters to a specific test and to the function of the product within the assembly, including where some components come from the previous roof build-up. Changing the layers can reveal limitations that one favourable board property does not eliminate. In the inspection and the repair design, retain the declared variant and the documentation of the load-bearing capacity and fire requirements of the assembly.

Cost of recreating details

In the offer, give the full Kingspan product designation and the board thickness. Assess the proposed substitution by its effects on the whole assembly, not only by the shared PIR designation. In a renovation quotation for ‘polyurethane insulation’, analyse the proposal to replace one Kingspan board with another of a similar name or the same surface colour.

Compare offers for different Kingspan boards together with the changes needed in the other layers, and confirm the final scope after identifying the necessary repairs. The existing condition affects the scope of the contract, because a price difference may result from a different application rather than from savings with an identical effect. Once the layers have been exposed, the equivalence criteria can be reliably agreed before approving the purchase and changing the construction documentation. Before finally ordering the material, confirm with the contractor responsible for preparing the old part the required thermal resistance, geometry, method of fixing and the cost of adapting the adjacent layers.

7 branches. Materials closer to your project.

Izoprofil.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project