XPS insulation
XPS under a foundation slab. What should the structural engineer check?
At a glance
A foundation slab may rest on a layer of thermal insulation if the design provides for this. In such an arrangement, XPS has a different task from a thin board bonded to a wall. It carries long-term actions and influences the deformation of the entire support. Extruded polystyrene must therefore be selected on the basis of calculations and the data for the specific product. The designation of a common compression class is not on its own an answer to the question of whether the material is suitable under a given house. Walls, columns and heavy items of equipment transmit forces at specific points. The foundation slab distributes them in accordance with its construction and support. XPS must be assessed within this actual arrangement.

The building load is not uniform
Simply dividing the weight of the house by the foundation area can overlook local stresses. The designer needs data on the structure, geometry and anticipated use of the building.
Interaction with the ground and the base layer is also significant. Extruded polystyrene does not replace ground investigation or proper site preparation. If the support varies locally, the whole slab behaves differently. The selection of XPS should therefore be considered together with the foundation and the ground. Only then can it be assessed whether the assumed displacements will remain consistent with the requirements of the structure.
A short test does not describe many years of service
The CS(10) value describes the behaviour of the material in a specific compression test. It should not be treated as a permissible permanent compressive stress. For XPS beneath a foundation, data on creep, i.e. the change in deformation under long-term load, are also important. It is precisely these displacements that may matter for the building, even before the limiting values from a short-term test have been reached.
Extruded polystyrene should have documentation that allows the intended application to be assessed. If the creep parameter has not been declared, it cannot be assumed to be zero. A proper basis for calculation is needed. XPS should be compared under the same assumptions of time, deformation and operating conditions. The difference between the figures 300, 500 and 700 alone does not exhaust this issue.
Thermal thickness and structural thickness are interrelated
The XPS layer is to provide the required limitation of heat losses. Its thickness results from the thermal analysis of the building and the details at the edges. Increasing the thickness, however, also affects the total deformation of the layer. The thermal and structural solution should therefore be agreed together. No further layer of insulation should be added on site without checking the effects of that change.
The multilayer arrangement requires confirmation for the specific board and application. Extruded polystyrene must not be laid in any number of layers simply because they are easy to lay. The documentation may limit the thickness, configuration or method of execution. XPS must be selected so that the complete layer corresponds both to the calculations and to the installation conditions envisaged for the chosen solution.
Support and services must be planned
The substrate under XPS should have adequate load-bearing capacity and evenness. A loose spot or protrusion can alter the load distribution. Checking these properties precedes laying the boards. Particular attention is required for penetrations, installation routes and local depressions. Making openings must not lead to accidental weakening of the support under a part of the structure that carries large forces.
Equally important is protecting the XPS during reinforcement and concreting. Spacers, worker movement and material storage should correspond to the construction technology. Extruded polystyrene is not resistant to arbitrary point loads simply because it will ultimately be under the foundation. The organisation of works must protect the continuity of the layer and prevent its local damage before covering.
Water can change the conditions beneath the foundation
When selecting the insulation, the water conditions and the method of protecting the building are taken into account. The low water absorption of XPS does not replace waterproofing or buoyancy analysis. The sequence of sealing layers should comply with the design. The connections at edges and penetrations must also be resolved. Later access to this part of the foundation is very limited, so the execution stage is of particular importance.
A dry excavation must not be treated as proof that there will be no future contact with water. Extruded polystyrene is selected for the anticipated conditions, not only for the weather on the day of installation. XPS should have properties and documents corresponding to these assumptions. Any change in the ground or the foundation level requires reassessment, because it can affect more than just the thermal insulation.
Approved material before delivery
Manufacturers of XPS include, among others, Austrotherm, Synthos and Finnfoam. The specific product must be approved according to the project requirements. The name Styrodur does not describe the ability to perform under a foundation slab. The order should include the required mechanical properties, thickness, edges and documentation of use. Changing the product to a similarly looking one requires checking its data.
Before concreting, the substrate, the laying of the XPS and the installation details are inspected and accepted. It is worth keeping photographs and markings of the delivered material. Extruded polystyrene can enable continuous foundation insulation, but this advantage does not release anyone from the calculations. The safest solution is a joint structural and thermal decision, confirmed by documents and correct execution on site.