How do I prepare a quick thermal calculation for a wall and check for moisture?

A quick calculator helps compare insulation thicknesses. However, it will not identify damp masonry or a poorly detailed reveal. For the result to be useful, the actual wall and its operating conditions must be described. Heat loss, surface temperature and the risk of moisture within the construction are checked separately. Record the layer build-up from inside to outside. For each layer, give the thickness and thermal properties. In an existing building, do not automatically assume that the wall matches a typical solution from the year of construction. An air cavity, a different type of block or later cladding can change the result.

By |2026-11-14T09:33:00+01:002023-01-25|Technology and applications|Comments Off on How do I prepare a quick thermal calculation for a wall and check for moisture?

Is a mineral wool panel non-combustible and what does A2-s1,d0 actually mean?

Mineral wool and a finished insulated wall panel are not the same product. The panel also contains facings, adhesives and joints. The classification of the whole product must therefore be checked. The A2-s1,d0 designation is also not a substitute for EI. The first concerns reaction to fire, the second the behaviour of the wall in a specific assembly. The core is one of the panel's components. In the finished element it works together with the steel facings and the other materials. The properties of the mineral wool alone cannot automatically be attributed to the whole product. The declaration relating to the specific panel must be read.

By |2026-11-14T09:32:55+01:002023-01-15|Technology and applications|Comments Off on Is a mineral wool panel non-combustible and what does A2-s1,d0 actually mean?

How to read reviews of panel and sheet suppliers and hall contractors?

Reviews can point to questions worth asking before ordering. They do not, however, replace a material description or checks on the contractor. A brief praise of the price says less than an account of dimensional conformity and deadline. It is best to read comments through the lens of your own scope: buying panels, sheet delivery or building a complete hall. Buying a few sheets and building a complete hall are different tasks. Good service at warehouse collection does not automatically confirm the quality of structural works. Note whether the description concerns sales, transport, installation or the whole process. Only then can it be related to your own need.

By |2026-11-14T12:00:16+01:002023-01-07|Technology and applications|Comments Off on How to read reviews of panel and sheet suppliers and hall contractors?

Garage roofing: T18 sheets, T35 sheets or sandwich panels?

The choice of garage roof covering depends primarily on whether the garage is heated, not on the price per square metre alone. Check the roof pitch, support spacing and snow and wind loads, as these parameters determine whether a given option is permissible. In a cold garage, condensation and efficient ventilation are often key; in a heated one, the entire building envelope matters. Leave the final decision on the profile or panel to the designer, because roofs that look similar from outside may have a completely different cross-section.

By |2026-11-14T18:55:56+01:002023-01-02|Technology and applications|Comments Off on Garage roofing: T18 sheets, T35 sheets or sandwich panels?

Can you walk on an insulated panel roof during an inspection?

Do not assume an insulated panel roof is safe to walk on. Before an inspection, establish an access route and suitable protection. Ideally, plan both when choosing the roof covering, particularly if equipment on the roof will need servicing. A foot places a concentrated load on a small area. The top facing can deform locally even when the panel as a whole safely carries a distributed load. A snow load table alone therefore cannot establish that the roof is safe to walk on. The facings, core, supports and position of the load relative to the ribs and supports all matter. No single rule for foot placement applies to every profile.

By |2026-11-14T15:38:32+01:002022-12-29|Technology and applications|Comments Off on Can you walk on an insulated panel roof during an inspection?

Roof rafters: dimensions, types and what affects the price

The cross-section of a rafter is not determined by the roof covering alone, but by a set of structural parameters. Check the span between supports, spacing, timber class, support arrangement and loads — only these allow the beam's behaviour to be assessed. The length from eaves to ridge alone does not describe its performance, especially with intermediate support. When ordering, give the length from the documentation and the number of pieces; a dimension from a handbook does not replace a design for a specific house. Compare offers using the same material specification and scope of processing.

By |2026-11-14T22:26:40+01:002022-12-24|Technology and applications|Comments Off on Roof rafters: dimensions, types and what affects the price

Single-sided and double-sided fence slats. Two different decisions hidden in one word

The word "double-sided" can describe either the sheet surface or the way the slats are arranged. These are two different issues. A slat with a decorative colour on both sides can still form a single row. Conversely, two rows can be built from different finish variants if the system allows it. When talking about a fence, it is therefore worth using full descriptions. That way the metal slats will arrive in the ordered version, and the expected degree of screening will follow from the actual arrangement. A decoratively double-sided variant has a finish intended to be viewed from both sides. However, its exact description must be established. Do both surfaces have the same colour? Do the gloss and texture match? Is the woodgrain decor also present on the back? The word "coated" alone does not answer all these questions. The sheet may be protected on both sides yet look different on the front and the back.

By |2026-11-15T17:18:38+01:002022-12-19|Technology and applications|Comments Off on Single-sided and double-sided fence slats. Two different decisions hidden in one word

Choosing panels for cattle sheds, poultry houses and pig buildings

In a livestock building, the envelope works under different conditions than in a dry warehouse. Humidity, chemical compounds and regular cleaning matter. The surfaces, seals and fixings must be selected. The core thickness is important but does not determine the durability of the entire roof and walls. State the building's purpose, the temperature and humidity conditions and the ventilation method. Also describe the agents used during washing and disinfection. A cattle shed, poultry house and piggery do not have to have identical operating conditions. A general phrase 'agricultural use' is not enough.

By |2026-11-14T11:58:33+01:002022-11-29|Technology and applications|Comments Off on Choosing panels for cattle sheds, poultry houses and pig buildings

What to do when you find a roof leak

After noticing a leak, limit the damage inside and have the cause determined. The position of the stain on the ceiling need not lie directly beneath the damaged covering. Water can travel through the roof layers. Condensation can produce a similar symptom. Do not go onto a wet roof slope in search of a hole. An effective repair begins with a safe inspection and with distinguishing the source of the moisture. Move objects away from the drip point and restrict access to the affected part of the room. If water is near electrical installations, an assessment and safe handling by a competent person are required. Do not touch wet equipment. A sagging ceiling lining or plaster coming loose may pose an additional hazard to people beneath it.

By |2026-11-14T15:40:36+01:002022-11-28|Technology and applications|Comments Off on What to do when you find a roof leak

What does the Passive House standard require?

Whether a home meets the passive house standard depends on the energy balance of the whole building. Before selecting insulation boards, the designer assesses heat loss through the building envelope and its junctions, as well as the effects of windows and ventilation. Thicker roof insulation cannot seal an air leak around a window. The calculations therefore need to be backed up by good workmanship and an airtightness test on the completed envelope. When comparing designs, ask which floor area was used to calculate heating demand. This figure serves a different purpose from an individual household’s heating bill.

By |2026-11-14T22:27:25+01:002022-11-25|Technology and applications|Comments Off on What does the Passive House standard require?