Fixing holes in corrugated fibre cement: why clearance matters

A larger hole around the screw shank can raise doubts. Clients sometimes expect a tight fit, which seems more solid. With profiled roofing, that intuition can be misleading. Fibre cement sheets need fixings designed with adequate clearance. Asbestos-free fibre cement is a rigid material, and the roof moves under environmental conditions and loads. The right hole helps limit stress without sacrificing weathertightness. On a roof, components made of different materials meet. They respond differently to temperature, moisture and load. A timber batten, a steel purlin and a sheet do not have to behave identically. Dimensional tolerances and structural deflection add to this. The fixing should therefore not block every minor movement by jamming the shank in the hole.

By |2026-11-15T17:20:39+01:002023-03-16|Technology and applications|Comments Off on Fixing holes in corrugated fibre cement: why clearance matters

Floor renovation with Recticel Eurofloor: fitting insulation beneath the threshold

During a renovation, the height of the existing doors and thresholds limits the choice of floor build-up. Recticel Eurofloor can help accommodate the insulation. First, however, the levels must be measured accurately and the substrate assessed for moisture and evenness. Recticel Eurofloor has a rigid PIR foam core with a multi-layer, gas-tight foil printed with a grid on both sides. The manufacturer specifies it for thermal insulation of floors, including floors with underfloor heating. During the pre-renovation survey, check the floor where the heating installation is located in the layers above the thermal insulation. Eurofloor must be placed in the correct floor build-up together with the planned heating installation before the scope of demolition is determined and the old floor structure is prepared.

By |2026-11-16T00:10:43+01:002023-03-14|Technology and applications|Comments Off on Floor renovation with Recticel Eurofloor: fitting insulation beneath the threshold

Fine profiling and wide ribs: how a fence picket’s shape affects it

On pickets you can see narrow grooves, wider pressings and larger smooth areas. These details affect the appearance and the geometry of the element. However, they do not create a simple quality ranking. More lines on the surface do not automatically mean a better product. Metal pickets must be assessed as a complete cross-section, together with thickness and support. The term “micro-profiling” is sometimes used descriptively, so it is worth checking the actual drawing instead of basing the choice on the word alone. A photo of the face mainly shows shadows and surface lines. It can hide the depth of the ridge and the way the sides are shaped. A cross-section drawing reveals these differences. It is worth seeing where the material projects forward and where it recedes towards the structure. Only then can you tell whether two similarly looking models have a comparable geometry.

By |2026-11-15T17:19:07+01:002023-03-09|Technology and applications|Comments Off on Fine profiling and wide ribs: how a fence picket’s shape affects it

Removing moss from tile-effect metal roofing without damaging the coating

Before removing moss from coated steel roofing, establish whether it really is moss and check that the coating beneath the deposit is continuous. From ground level the appearance of the deposit can be misleading, so examine safely taken close-ups. The type of soiling and the condition of the finish determine the choice of method and product. Also check whether the problem is confined to an area under a tree, behind a chimney or near accumulated leaves. If corrosion or detached coating is visible, an assessment for repair is needed, as a cleaning product alone will not restore the steel.

By |2026-11-14T18:56:17+01:002023-03-07|Technology and applications|Comments Off on Removing moss from tile-effect metal roofing without damaging the coating

Roof renovation with Powerdeck F: assessing old layers and adhesion

In a roof renovation, poor adhesion of the old layer can limit the entire new solution. Before laying Powerdeck F, it must be assessed, as must moisture and unevenness. The new board will not automatically strengthen the material to which it is bonded. Recticel Powerdeck F has a PIR core coated on both sides with a mineralised glass fleece. The product is intended for flat roofs with a suitably selected covering. During the pre-renovation inspection, check the mineralised glass fleece of Powerdeck F as the surface that works together with the covering. The facing of Powerdeck F must be matched to the materials adjoining it in the adopted roof system before the scope of demolition is determined and the old building envelope is prepared. The new surface does not solve everything: a similar colour of the PIR core does not determine the compatibility of the surface with the selected membrane.

By |2026-11-16T00:10:48+01:002023-03-01|Technology and applications|Comments Off on Roof renovation with Powerdeck F: assessing old layers and adhesion

How an eaves flashing directs water from the roof into the gutter

The eaves gutter flashing serves to collect water flowing down the roof slope and direct it into the gutter, while also shielding the eaves zone. At handover, it is worth checking not only the continuity of the flashing and its laps, but above all whether water from the covering actually reaches the gutter rather than passing behind it or under the covering. Equally important is preserving the required ventilation beneath the metal sheet. The shape of the flashing should follow the specific eaves detail, not merely the width of the available sheet.

By |2026-11-14T22:28:27+01:002023-02-28|Technology and applications|Comments Off on How an eaves flashing directs water from the roof into the gutter

Adding PIR insulation to an old flat roof: checking the layers beneath

New PIR boards can improve the thermal performance of an old flat roof. First, however, the condition of the covering, the substrate and the concealed layers must be established. Key points are damp areas, drains and the height of the parapet. A good renovation plan combines thermal insulation with repair of these details. PIR boards for a flat roof are selected according to how the covering is constructed. Aluminium laminate, glass fleece and bitumen-coated facing are not interchangeable surfaces. The old covering can become a substrate only after its condition and compatibility have been assessed. Not every adhesive and new facing are compatible with the surface left in place. If the old waterproofing is retained, its role in the new build-up must be established.

By |2026-11-16T00:09:52+01:002023-02-27|Technology and applications|Comments Off on Adding PIR insulation to an old flat roof: checking the layers beneath

Renovating a floor with PIR: fitting insulation below existing thresholds

In an old floor there is often not enough room to improve the thermal insulation. PIR boards can help thanks to the small thickness needed to achieve a given thermal resistance. Before buying, however, you must uncover the actual cross-section, measure the levels and match the build-up to the loads. PIR boards are useful in a floor when the available height is limited. Low thermal conductivity allows an effective insulation layer to fit under the screed. After removing the floor covering it is worth measuring the height to the threshold again. Old drawings may not show the actual thickness of all the layers left in place. Removing the old finish often changes what is known about the available space. It is worth checking the level of the substrate in several places, not only at the door.

By |2026-11-16T00:09:53+01:002023-02-20|Technology and applications|Comments Off on Renovating a floor with PIR: fitting insulation below existing thresholds

Choosing a roofer and agreeing who is responsible for each part of the job

When choosing a roofer, check above all their experience with the specific covering and roof geometry, not just the overall number of projects. Ask for examples of details such as the valley, eaves and chimney junction, and for documentation of the layers before they are covered. In the contract, allocate responsibility for measurement, materials and installation, and set out the stages of inspection and the rules for settling additional work. Remember that installing modular metal tiles differs from a roof made of sandwich panels, so familiarity with one system does not guarantee proficiency in the other.

By |2026-11-15T02:34:49+01:002023-02-15|Technology and applications|Comments Off on Choosing a roofer and agreeing who is responsible for each part of the job

What determines the durability of a wall made of insulated panels with mineral wool?

The service life of a mineral wool panel cannot honestly be reduced to a single number of years. The wall works as a system of facings, core, locks and fixings. Water, surface damage and environmental conditions are of major importance. Durability should be planned at the plinth, corners and places that will later be difficult to reach. The steel facings protect the core and work with it to carry loads. The mineral wool provides insulation and participates in the performance of the whole element. The connection between the layers is essential. Therefore the condition of the external paint does not describe all the properties of the panel.

By |2026-11-14T09:31:59+01:002023-02-09|Technology and applications|Comments Off on What determines the durability of a wall made of insulated panels with mineral wool?