Five roofing faults to look for before handover

The key decision before accepting a metal roof is whether the inspection will cover layers that will soon disappear beneath the covering. It is worth checking the geometry of the substrate, the batten spacing, the method of fixing, the condition of the coating, the continuity of ventilation and the routes for water drainage. Most problems stem from faults that are visible before work is completed, so photographs and stage-by-stage inspections offer more than a view of the finished slope from the ground. Documentation of the stages helps catch errors before correcting them becomes expensive.

By |2026-11-14T22:28:44+01:002022-07-14|Technology and applications|Comments Off on Five roofing faults to look for before handover

Flat roof renovation with termPIR WS: checking beneath the old membrane

Covering an old roof with another layer does not solve the problem of hidden moisture. Before installing termPIR WS, the condition of the existing materials must be assessed. Only then can it be determined what stays, what needs to be removed and where new details will be required. termPIR WS consists of a PIR core with a vapour-permeable glass fleece facing on both sides. This is a different surface from a vapour-tight aluminium laminate. During the pre-renovation inspection, check the surface of the flat roof where the board facing is to work together with the covering. The termPIR WS glass fleece must be matched to the layers and the fixing method of the chosen roof covering before the scope of demolition is determined and the old assembly is prepared.

By |2026-11-16T00:10:13+01:002022-07-03|Technology and applications|Comments Off on Flat roof renovation with termPIR WS: checking beneath the old membrane

Which measurements are needed for made-to-measure chimney flashings?

Chimney flashings are difficult to order from a single photo. You need the dimensions of the penetration, the roof pitch and information about the covering. Each side of the chimney may have a different role in draining water. That is why it is worth preparing the measurements as a simple set of drawings. This will make it easier to discuss with the contractor and to compare quotes that actually cover the same scope. The final solution must be consistent with the roof penetration design. The clearest way to describe the chimney is as the lower side, the upper side and the two lateral sides. This division relates to water runoff and reduces ambiguity. The term front can be misleading when one person is looking from the street and another from the ridge. The sketch should indicate the direction down the roof.

By |2026-11-15T02:36:46+01:002022-06-19|Technology and applications|Comments Off on Which measurements are needed for made-to-measure chimney flashings?

Thermano Roof when replacing a roof covering: planning additional insulation

Replacing the roof covering is an opportunity to improve the insulation, but it also reveals the condition of the old structure. Thermano Roof should be selected after that structure has been assessed. What matters are the eave levels, the junctions at the walls and the way the new layer build-up transfers loads. Thermano Roof is a rigid PIR board with a gas-tight multilayer aluminium facing on both sides. The manufacturer specifies it for, among other things, flat roofs and above-rafter insulation. During the pre-renovation inspection, check the pitched roof slope on which the insulation is to be placed above the timber rafters. The Thermano Roof layer above the rafters must be tied in with the terminations at the eaves and openings before the scope of demolition is determined and the old building envelope is prepared.

By |2026-11-16T00:10:27+01:002022-05-23|Technology and applications|Comments Off on Thermano Roof when replacing a roof covering: planning additional insulation

When does a roof need repair and when does it need replacing?

The condition of the whole roof assembly and the cause of the fault, not the age of the covering, should determine whether to repair or replace. Before comparing costs, establish the water's path: it may travel along the membrane or flashing and appear far from the point of entry. Check whether the problem is limited and can be permanently removed, or whether it involves widespread corrosion, repeated leaks or damaged layers. Also distinguish a leak from condensation. A diagnosis from outside and from the accessible interior allows the scope of work to be matched to the actual cause.

By |2026-11-15T02:35:11+01:002022-04-28|Technology and applications|Comments Off on When does a roof need repair and when does it need replacing?

Roof pitch and selection of the fibre cement sheet system

The roof angle affects the rate of water drainage and the working conditions of the joints. It cannot be treated as a secondary dimension when choosing a covering. Fibre cement sheets have pitch requirements set out in the documentation for the given system. A single figure cannot be transferred to all profiles. Asbestos-free fibre cement may be a good solution for a pitched roof, but its suitability must be confirmed for the specific roof slope and local conditions. In documents, pitch is sometimes stated in degrees and sometimes in percentages. These are different ways of representing the same geometry, not figures used interchangeably. A percentage means the ratio of the rise in height to the horizontal distance.

By |2026-11-15T17:20:23+01:002022-04-17|Technology and applications|Comments Off on Roof pitch and selection of the fibre cement sheet system

Will roof panels available from stock fit the length of your roof?

A ready batch of sheets can speed up the purchase if it matches the roof dimensions. The total square metres alone do not confirm this. You need to know the length of each element, its profile and the preparation of the ends. Before choosing material available from stock, draw it on the actual supports and the edges of the roof slope. Measure along the slope, in line with the position of the panel. The horizontal projection is not the same as the length down the slope. Allow for the intended eaves and the termination at the ridge or wall. The dimensions should follow from a specific detail, not from an arbitrary addition to the measurement.

By |2026-11-14T12:01:49+01:002022-04-14|Technology and applications|Comments Off on Will roof panels available from stock fit the length of your roof?

Roof underlay, vapour control layer or protective film?

Begin by deciding where each layer belongs within the roof assembly, not by the name on the roll. The term ‘roofing foil’ covers materials with different jobs: the membrane beneath the covering helps drain water and vapour, the layer on the interior side restricts moisture ingress, and the protective foil on sheet metal serves yet another purpose. Check the diffusion resistance, intended use and location required by the roof design. Swapping layers can trap moisture in the roof or leave gaps, so specify the material name, parameters and fixing detail on the order.

By |2026-11-15T02:34:32+01:002022-04-11|Technology and applications|Comments Off on Roof underlay, vapour control layer or protective film?

What makes coated steel sheet suitable for roofing?

The choice of roofing sheet depends on how the entire layer system matches the building's conditions, not on colour or sheet thickness alone. It is worth checking the coating documentation, the product's intended use and the maintenance requirements, especially in coastal areas or near an industrial plant. The steel core provides mechanical properties, a metallic coating protects it, and the outer layers determine colour, texture and part of the environmental resistance. Their arrangement can vary, so two similar-looking sheets may behave differently under prolonged moisture or scratching.

By |2026-11-14T22:28:00+01:002022-04-07|Technology and applications|Comments Off on What makes coated steel sheet suitable for roofing?

Roofs without overhangs: design, advantages and detailing challenges

A roof without eaves is a system in which the slope ends at the façade rather than projecting beyond the wall. Before choosing this variant, check above all the roof-edge cross-section: the junction of covering, insulation and drainage. This detail determines whether water reaches the gutter rather than the wall or the space behind the insulation. It is also worth establishing how ventilation under the covering will work and whether service access to the gutter is provided. A visualisation alone will not show these details, so the design should clearly define the solution for each layer.

By |2026-11-14T22:26:39+01:002022-04-03|Technology and applications|Comments Off on Roofs without overhangs: design, advantages and detailing challenges
Back to top