Buying 40 mm roof panels in RAL 3009: what to check for a 13.5 m length

A 13.5 m roof panel can reduce the number of joints on the roof slope, but requires careful logistics. With a thickness of 40 mm, the parameters and the permitted range of application must be checked. The RAL 3009 colour and second grade are further characteristics of a specific offer. None of them alone confirms the roof's load-bearing capacity. If the offer includes a length of 13.5 m, the feasibility of exactly this configuration must be confirmed. Permissible lengths may depend on thickness, colour and panel construction. The maximum value from the catalogue should not be applied to every variant.

By |2026-11-14T11:59:32+01:002024-10-06|Technology and applications|Comments Off on Buying 40 mm roof panels in RAL 3009: what to check for a 13.5 m length

How to connect a rainwater gully to a downpipe

A silt trap captures some leaves and sediment, but it does not replace a correctly designed drainage system as a whole. Before buying, check the diameter and shape of the downpipe and the outflow pipe, as well as the flow direction and access to the basket once the pipe is connected. Set the cover height relative to the finished surface, not the temporary ground, and choose a model with a load capacity suited to the installation location. The connection to the pipes should be stable and stress-free. After installation, carry out a flow test and observe the entire drainage run.

By |2026-11-14T22:28:24+01:002024-09-26|Technology and applications|Comments Off on How to connect a rainwater gully to a downpipe

How do you match wall and roof panel lengths to building dimensions?

Wall and roof panels are available in various production lengths. However, the catalogue maximum is not the right length for every order. Thickness, colour, support and transport all matter. The dimension must be determined from the building detail. Only then is it worth deciding whether to order one element or several sections. An example PIR wall family covers lengths from 2 to 15.8 m. The roof panel from this group has a range up to 16 m. This does not mean every combination of thickness and colour is available at the upper limit. The length of a specific order requires confirmation.

By |2026-11-14T12:00:50+01:002024-09-20|Technology and applications|Comments Off on How do you match wall and roof panel lengths to building dimensions?

Which roof coverings suit contemporary house designs?

The choice of roofing for a contemporary house depends above all on the roof pitch, the structure and how the details are resolved, not on how it looks in a photograph. Before comparing materials, check the project's provisions for colour and geometry and the local requirements; only within those limits should you assess modular metal tiles, trapezoidal sheeting or sandwich panels. Leave the final selection to the designer, since it is the designer who verifies whether a given profile and format suit the specific roof slope and its edges.

By |2026-11-14T18:55:48+01:002024-09-19|Technology and applications|Comments Off on Which roof coverings suit contemporary house designs?

When should you choose PIR 120 × 60 cm and when a 120 × 240 cm board?

A large board reduces the number of joints, while a small one makes work easier in tight spaces. The choice of PIR format should be determined by the dimensions of the building element and the transport route. A distinction must also be made between the external dimension and the coverage area after the edges are joined. Simply dividing the number of metres of wall by the board area can result in too small an order. The 120 × 60 cm format is nominally 0.72 m². The 120 × 240 cm format gives 2.88 m², i.e. four times more. These figures describe rectangles with the given dimensions. If the edges overlap, the actual coverage may be smaller. Dimensions specific to the selected product are required.

By |2026-11-14T09:33:51+01:002024-09-13|Technology and applications|Comments Off on When should you choose PIR 120 × 60 cm and when a 120 × 240 cm board?

How to compare panel prices without ordering more than you need

The lowest price per metre of panel does not necessarily mean the cheapest wall. If the lengths fit the building poorly, some of the material will end up as waste. Transport, flashings and fixings come on top. A favourable purchase means comparing a complete set with the required parameters. Only then does a discount have real significance. First, note the required core, thickness, facings and coatings. Establish the necessary parameters and the application. Without this, you might accidentally compare a wall panel with a roof panel, or first-grade material with a batch of unspecified deviations.

By |2026-11-14T11:59:19+01:002024-09-10|Technology and applications|Comments Off on How to compare panel prices without ordering more than you need

How can you insulate a 1990s house from the inside without renovating the entire façade?

Preserving the façade can matter when the house is already finished or stands on a tight plot. Internal insulation may then be a variant worth considering. However, it is not chosen based on the year of construction alone. Data on the wall, an assessment of moisture and a plan for the junctions are needed. It is worth starting the renovation with a survey, not with buying boards. Houses from the 1990s have various wall constructions. There may be cavities, cladding layers and insulation of unknown condition. An archived design is helpful, but it is worth comparing it with the building. Later extension or repair work may have changed some of the building elements.

By |2026-11-14T09:33:34+01:002024-09-04|Technology and applications|Comments Off on How can you insulate a 1990s house from the inside without renovating the entire façade?

Preparing an occupied home for a photovoltaic roof replacement

Replacing a roof with a photovoltaic roof in an occupied home also requires planning on the part of the residents. Access for the crews must be agreed, the attic secured, and it must be clear when disruptions may occur. An integrated system allows work on the roof covering and the energy system to be carried out according to a shared schedule. This makes organisation easier when the scope is clearly described. Good preparation reduces stress and helps maintain control over the renovation without daily improvisation. It is worth discussing working hours, access routes and areas that residents will not be able to use. A contact for the person making decisions on site is important. The way information about schedule changes is communicated should also be established.

By |2026-11-15T17:20:02+01:002024-08-21|Technology and applications|Comments Off on Preparing an occupied home for a photovoltaic roof replacement

Choosing between tile-effect metal roofing and bitumen shingles

Compare tile-effect metal roofing and bituminous shingles as complete roof systems. They differ in format, substrate and installation method. Pitch, roof plane geometry and attic conditions all matter. Metal roofing can reduce the weight of the covering itself, while the small elements of shingles make work easier on certain shapes. Neither material removes the need for a correct substrate, ventilation and flashings. Tile-effect metal roofing is usually installed on a batten and counter-batten grid. Batten spacing corresponds to the profile and the module length. The substrate must form an even plane and be properly supported at the eaves. The underlay drains away water that may appear beneath the covering. Its selection and installation method are part of the overall roof design.

By |2026-11-14T15:40:19+01:002024-08-20|Technology and applications|Comments Off on Choosing between tile-effect metal roofing and bitumen shingles

PIR boards in renovation: when their construction offers a practical benefit

In renovation, PIR boards are often considered because of limited space. Before choosing a thinner layer, however, the condition of the old building element must be checked. The new material will change the conditions under which it performs. Good investigation allows the advantages of PIR to be used without covering up existing problems. Polyurethane insulation made from prefabricated boards has the properties declared for a factory-made product. This does not mean that installation ceases to matter. Cutting, joints and contact with other layers still affect the performance of the building element. The board's document and the laying instructions describe two complementary areas. The names of materials found under the finish are often uncertain. An old light-coloured core is not enough to determine its properties.

By |2026-11-16T00:09:32+01:002024-08-16|Technology and applications|Comments Off on PIR boards in renovation: when their construction offers a practical benefit