Roof renovation with Powerdeck F: assessing old layers and adhesion

In a roof renovation, poor adhesion of the old layer can limit the entire new solution. Before laying Powerdeck F, it must be assessed, as must moisture and unevenness. The new board will not automatically strengthen the material to which it is bonded. Recticel Powerdeck F has a PIR core coated on both sides with a mineralised glass fleece. The product is intended for flat roofs with a suitably selected covering. During the pre-renovation inspection, check the mineralised glass fleece of Powerdeck F as the surface that works together with the covering. The facing of Powerdeck F must be matched to the materials adjoining it in the adopted roof system before the scope of demolition is determined and the old building envelope is prepared. The new surface does not solve everything: a similar colour of the PIR core does not determine the compatibility of the surface with the selected membrane.

By |2026-11-16T00:10:48+01:002023-03-01|Technology and applications|Comments Off on Roof renovation with Powerdeck F: assessing old layers and adhesion

How an eaves flashing directs water from the roof into the gutter

The eaves gutter flashing serves to collect water flowing down the roof slope and direct it into the gutter, while also shielding the eaves zone. At handover, it is worth checking not only the continuity of the flashing and its laps, but above all whether water from the covering actually reaches the gutter rather than passing behind it or under the covering. Equally important is preserving the required ventilation beneath the metal sheet. The shape of the flashing should follow the specific eaves detail, not merely the width of the available sheet.

By |2026-11-14T22:28:27+01:002023-02-28|Technology and applications|Comments Off on How an eaves flashing directs water from the roof into the gutter

Adding PIR insulation to an old flat roof: checking the layers beneath

New PIR boards can improve the thermal performance of an old flat roof. First, however, the condition of the covering, the substrate and the concealed layers must be established. Key points are damp areas, drains and the height of the parapet. A good renovation plan combines thermal insulation with repair of these details. PIR boards for a flat roof are selected according to how the covering is constructed. Aluminium laminate, glass fleece and bitumen-coated facing are not interchangeable surfaces. The old covering can become a substrate only after its condition and compatibility have been assessed. Not every adhesive and new facing are compatible with the surface left in place. If the old waterproofing is retained, its role in the new build-up must be established.

By |2026-11-16T00:09:52+01:002023-02-27|Technology and applications|Comments Off on Adding PIR insulation to an old flat roof: checking the layers beneath

Renovating a floor with PIR: fitting insulation below existing thresholds

In an old floor there is often not enough room to improve the thermal insulation. PIR boards can help thanks to the small thickness needed to achieve a given thermal resistance. Before buying, however, you must uncover the actual cross-section, measure the levels and match the build-up to the loads. PIR boards are useful in a floor when the available height is limited. Low thermal conductivity allows an effective insulation layer to fit under the screed. After removing the floor covering it is worth measuring the height to the threshold again. Old drawings may not show the actual thickness of all the layers left in place. Removing the old finish often changes what is known about the available space. It is worth checking the level of the substrate in several places, not only at the door.

By |2026-11-16T00:09:53+01:002023-02-20|Technology and applications|Comments Off on Renovating a floor with PIR: fitting insulation below existing thresholds

Choosing a roofer and agreeing who is responsible for each part of the job

When choosing a roofer, check above all their experience with the specific covering and roof geometry, not just the overall number of projects. Ask for examples of details such as the valley, eaves and chimney junction, and for documentation of the layers before they are covered. In the contract, allocate responsibility for measurement, materials and installation, and set out the stages of inspection and the rules for settling additional work. Remember that installing modular metal tiles differs from a roof made of sandwich panels, so familiarity with one system does not guarantee proficiency in the other.

By |2026-11-15T02:34:49+01:002023-02-15|Technology and applications|Comments Off on Choosing a roofer and agreeing who is responsible for each part of the job

What determines the durability of a wall made of insulated panels with mineral wool?

The service life of a mineral wool panel cannot honestly be reduced to a single number of years. The wall works as a system of facings, core, locks and fixings. Water, surface damage and environmental conditions are of major importance. Durability should be planned at the plinth, corners and places that will later be difficult to reach. The steel facings protect the core and work with it to carry loads. The mineral wool provides insulation and participates in the performance of the whole element. The connection between the layers is essential. Therefore the condition of the external paint does not describe all the properties of the panel.

By |2026-11-14T09:31:59+01:002023-02-09|Technology and applications|Comments Off on What determines the durability of a wall made of insulated panels with mineral wool?

How do I prepare a quick thermal calculation for a wall and check for moisture?

A quick calculator helps compare insulation thicknesses. However, it will not identify damp masonry or a poorly detailed reveal. For the result to be useful, the actual wall and its operating conditions must be described. Heat loss, surface temperature and the risk of moisture within the construction are checked separately. Record the layer build-up from inside to outside. For each layer, give the thickness and thermal properties. In an existing building, do not automatically assume that the wall matches a typical solution from the year of construction. An air cavity, a different type of block or later cladding can change the result.

By |2026-11-14T09:33:00+01:002023-01-25|Technology and applications|Comments Off on How do I prepare a quick thermal calculation for a wall and check for moisture?

Is a mineral wool panel non-combustible and what does A2-s1,d0 actually mean?

Mineral wool and a finished insulated wall panel are not the same product. The panel also contains facings, adhesives and joints. The classification of the whole product must therefore be checked. The A2-s1,d0 designation is also not a substitute for EI. The first concerns reaction to fire, the second the behaviour of the wall in a specific assembly. The core is one of the panel's components. In the finished element it works together with the steel facings and the other materials. The properties of the mineral wool alone cannot automatically be attributed to the whole product. The declaration relating to the specific panel must be read.

By |2026-11-14T09:32:55+01:002023-01-15|Technology and applications|Comments Off on Is a mineral wool panel non-combustible and what does A2-s1,d0 actually mean?

How to read reviews of panel and sheet suppliers and hall contractors?

Reviews can point to questions worth asking before ordering. They do not, however, replace a material description or checks on the contractor. A brief praise of the price says less than an account of dimensional conformity and deadline. It is best to read comments through the lens of your own scope: buying panels, sheet delivery or building a complete hall. Buying a few sheets and building a complete hall are different tasks. Good service at warehouse collection does not automatically confirm the quality of structural works. Note whether the description concerns sales, transport, installation or the whole process. Only then can it be related to your own need.

By |2026-11-14T12:00:16+01:002023-01-07|Technology and applications|Comments Off on How to read reviews of panel and sheet suppliers and hall contractors?

Garage roofing: T18 sheets, T35 sheets or sandwich panels?

The choice of garage roof covering depends primarily on whether the garage is heated, not on the price per square metre alone. Check the roof pitch, support spacing and snow and wind loads, as these parameters determine whether a given option is permissible. In a cold garage, condensation and efficient ventilation are often key; in a heated one, the entire building envelope matters. Leave the final decision on the profile or panel to the designer, because roofs that look similar from outside may have a completely different cross-section.

By |2026-11-14T18:55:56+01:002023-01-02|Technology and applications|Comments Off on Garage roofing: T18 sheets, T35 sheets or sandwich panels?
Back to top