Choosing a prefabricated steel frame to suit the wall cladding layout

A typical steel hall is not made up of randomly selected profiles. It has a defined geometry, frame layout and method of stabilisation. The prefabricated steel structures we offer allow you to choose one of the prepared variants. With sets available off the shelf, there is no need to wait for all components to be produced from scratch. The specific availability and collection date are confirmed for the selected series. Our duo-pitch structures are available in widths of 8, 10, 12, 14, 16, 18 and 20 metres. Individual series also differ in frame spacing. For the 8, 10 and 12 metre variants it is 4 metres. For widths from 14 to 20 metres, bays of 5 metres are used. These figures must be read together, as they describe the entire layout.

By |2026-11-15T02:36:25+01:002024-11-05|Technology and applications|Comments Off on Choosing a prefabricated steel frame to suit the wall cladding layout

Fence picket width: calculating spacing and material quantities

Picket width affects the rhythm of the bay, the number of elements and how the gaps are distributed. However, it cannot be assessed without the gap. A wide profile set more loosely can give a different impression than a narrow picket laid very densely. In offers, several different widths describing the same product are also found. Therefore, before calculating the order, it is necessary to establish which value refers to the finished infill. This is a simple step that protects against a serious quantitative error. The blank is the strip of sheet metal that goes for profiling. Part of it is allocated to bends and pressings. The finished picket is therefore narrower than the flat strip before processing. In one real configuration, a strip of width 156 mm yields a profile of width 115 mm. Therefore, pickets should not be counted according to the value describing the raw material.

By |2026-11-15T17:18:23+01:002024-11-01|Technology and applications|Comments Off on Fence picket width: calculating spacing and material quantities

Flat roof renovation with Utherm Roof BM: checking the substrate

When renovating with Utherm Roof BM, what matters is what the lower facing will come into contact with. The condition of the old covering can change the way preparation and fixing are carried out. Before ordering, it is therefore worth checking the substrate and the height that will remain at the outlets once the insulation has been added. Utherm Roof BM is a PIR board with different facings on either side. One surface is finished with a bituminised glass fleece. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. The pre-renovation inspection should cover two different surfaces of Utherm Roof BM: the bituminised and the mineralised one. During the survey of the existing build-up, the orientation of the bituminised and mineralised side of Roof BM must be established.

By |2026-11-16T00:11:55+01:002024-10-25|Technology and applications|Comments Off on Flat roof renovation with Utherm Roof BM: checking the substrate

Renovating with termPIR AL: fitting insulation without gaps in continuity

During a renovation, a few centimetres at the threshold, the parapet or the eaves often pose a problem. termPIR AL can help make use of the available space. At the same time, it is necessary to establish where the insulation will connect with the old layers and how airtightness is to be maintained at these points. termPIR AL has a rigid PIR foam core. On both sides there is a gas-tight laminate containing aluminium, paper and polyethylene. During the pre-renovation inspection, check the low exit threshold, where the new layers have limited height. The threshold must be connected to continuous thermal insulation of the wall and floor without leaving an exposed strip before determining the scope of demolition and preparing the old building element.

By |2026-11-16T00:10:07+01:002024-10-21|Technology and applications|Comments Off on Renovating with termPIR AL: fitting insulation without gaps in continuity

Choosing roof panel thickness after surveying the building

Choosing the roof panel thickness begins with the building's function and ends with a check of the entire building envelope. Thermal requirements, support spacing and roof geometry are needed. A thicker panel also changes the flashings and the length of the fasteners. It is therefore worth choosing it before ordering the remaining components, not only at the time of delivery. Determine whether the interior will be heated continuously, periodically, or remain cold. Add the expected temperature and the pattern of use. A workshop with frequently opened gates performs differently from a closed warehouse. Moisture from processes, wet vehicles or intensive work also affects the requirements for the building envelope and ventilation.

By |2026-11-14T15:38:34+01:002024-10-14|Technology and applications|Comments Off on Choosing roof panel thickness after surveying the building

Façade renovation with Thermano ETICS: thickness, sills and the render substrate

Changing the façade thickness affects window sills, flashings and the proportions of the reveals. Thermano ETICS should be assessed as such a complete system. During the renovation, the load-bearing capacity of the old substrate must also be confirmed, as must the way the new thermal insulation is connected to the existing elements. Thermano ETICS is a composite board made of PIR with an outer EPS layer 20 mm thick. The PIR part has gas-tight multilayer facings containing aluminium. During the pre-renovation inspection, check the cross-section of the façade board with the PIR core and the outer EPS layer 20 mm thick. The surface of Thermano ETICS must be identified as the outer EPS layer belonging to the composite before determining the scope of demolition and preparing the old building envelope.

By |2026-11-16T00:10:32+01:002024-10-11|Technology and applications|Comments Off on Façade renovation with Thermano ETICS: thickness, sills and the render substrate

Buying 40 mm roof panels in RAL 3009: what to check for a 13.5 m length

A 13.5 m roof panel can reduce the number of joints on the roof slope, but requires careful logistics. With a thickness of 40 mm, the parameters and the permitted range of application must be checked. The RAL 3009 colour and second grade are further characteristics of a specific offer. None of them alone confirms the roof's load-bearing capacity. If the offer includes a length of 13.5 m, the feasibility of exactly this configuration must be confirmed. Permissible lengths may depend on thickness, colour and panel construction. The maximum value from the catalogue should not be applied to every variant.

By |2026-11-14T11:59:32+01:002024-10-06|Technology and applications|Comments Off on Buying 40 mm roof panels in RAL 3009: what to check for a 13.5 m length

How to connect a rainwater gully to a downpipe

A silt trap captures some leaves and sediment, but it does not replace a correctly designed drainage system as a whole. Before buying, check the diameter and shape of the downpipe and the outflow pipe, as well as the flow direction and access to the basket once the pipe is connected. Set the cover height relative to the finished surface, not the temporary ground, and choose a model with a load capacity suited to the installation location. The connection to the pipes should be stable and stress-free. After installation, carry out a flow test and observe the entire drainage run.

By |2026-11-14T22:28:24+01:002024-09-26|Technology and applications|Comments Off on How to connect a rainwater gully to a downpipe

How do you match wall and roof panel lengths to building dimensions?

Wall and roof panels are available in various production lengths. However, the catalogue maximum is not the right length for every order. Thickness, colour, support and transport all matter. The dimension must be determined from the building detail. Only then is it worth deciding whether to order one element or several sections. An example PIR wall family covers lengths from 2 to 15.8 m. The roof panel from this group has a range up to 16 m. This does not mean every combination of thickness and colour is available at the upper limit. The length of a specific order requires confirmation.

By |2026-11-14T12:00:50+01:002024-09-20|Technology and applications|Comments Off on How do you match wall and roof panel lengths to building dimensions?

Which roof coverings suit contemporary house designs?

The choice of roofing for a contemporary house depends above all on the roof pitch, the structure and how the details are resolved, not on how it looks in a photograph. Before comparing materials, check the project's provisions for colour and geometry and the local requirements; only within those limits should you assess modular metal tiles, trapezoidal sheeting or sandwich panels. Leave the final selection to the designer, since it is the designer who verifies whether a given profile and format suit the specific roof slope and its edges.

By |2026-11-14T18:55:48+01:002024-09-19|Technology and applications|Comments Off on Which roof coverings suit contemporary house designs?