Renovating roof drainage with Kingspan Therma TT46 boards

Renovating roof drainage with Kingspan Therma TT46 boards requires reference to the actual geometry of the roof slopes, not only to the original plan. The Therma TT46 board is PIR insulation of variable thickness, with aluminium-containing facings on both sides, intended for forming falls on flat roofs; it can complement a system with Therma TR26 boards. Before the renovation, the roof area in which the thermal insulation is to work together with the direction of drainage must be identified, and the position of the outlets and obstructions must be established. This allows a continuous path for the water and the extent of demolition of the old building envelope to be planned, instead of correcting a single visible depression.

By |2026-11-16T04:49:56+01:002021-10-07|Technology and applications|Comments Off on Renovating roof drainage with Kingspan Therma TT46 boards

Kingspan Therma TR27 for roof repair and thermal insulation

Therma TR27 may fall within the scope of a roof repair, but its suitability depends on what you find beneath the existing covering. It is a PIR board with glass fibre facings on both sides; the catalogue specifies flat roof and terrace build-ups with mechanical fastening, bonding or ballasting in accordance with the system documentation. In a bonded build-up, the condition of the surface and the compatibility of the materials are decisive, so the old layers must be assessed before adopting a new method of laying the covering. The inspection should also cover the junction between the board and the first layer of the adopted covering — this junction co-determines the extent of demolition work and the preparation of the existing roof assembly.

By |2026-11-16T04:49:54+01:002021-09-14|Technology and applications|Comments Off on Kingspan Therma TR27 for roof repair and thermal insulation

Renovating a flat roof with Kingspan Therma TR26

Renovating a flat roof with Kingspan Therma TR26 boards begins with identifying the existing layers that are to remain in the building element and measuring their cross-section. New insulation will not repair the condition of the substrate or align the flashings by itself, so the scope of works must be established before ordering material. TR26 has a PIR core and a multilayer facing containing aluminium on both sides; the Polish catalogue provides for a concrete, steel or timber substrate with mechanically fixed or ballasted covering. The inspection also covers a flat roof with a low rooflight kerb, where little space remains for the new layers and the boards must be brought up to the vertical upstand without a break in the thermal insulation. The scope of demolition and the preparation of the old building element depend on this inspection.

By |2026-11-16T04:49:53+01:002021-08-30|Technology and applications|Comments Off on Renovating a flat roof with Kingspan Therma TR26

XPS in a heated and an unheated basement. Two different tasks

A basement can be part of a heated house or a cool utility room. This determines where the thermal insulation layer should run. XPS is often considered for walls in contact with the ground and for the floor. Extruded polystyrene combines low water absorption with properties useful under load. However, the benefit of using it differs between the two basement variants. First, you have to decide what conditions are to prevail in the basement. In a heated basement, the building components separating the interior from the ground and the outside air are insulated. XPS can form a continuous layer on the outside of the walls and in the floor, in accordance with the design. This limits heat flow through the basement storey.

By |2026-11-16T04:50:40+01:002021-08-28|Technology and applications|Comments Off on XPS in a heated and an unheated basement. Two different tasks

Renovating a wall from inside with termPIR AL GK: details that matter

When insulating from the inside, it is often the small areas that cause the most difficulty: corners, reveals and the spaces behind services. termPIR AL GK requires these junctions to be drawn out before work begins, because once the lining is closed, corrections become troublesome. termPIR AL GK is a composite. The insulation part made of PIR foam has a gas-tight facing on both sides, and on the room side there is a 12.5 mm plasterboard. During the pre-renovation inspection, examine the wall from the inside, where a single board is to provide both insulation and the substrate for the finish. The masonry behind termPIR AL GK must be assessed before it is sealed under the insulation and the new plasterboard surface, and before the scope of demolition is determined and the old partition prepared.

By |2026-11-16T00:10:15+01:002021-08-18|Technology and applications|Comments Off on Renovating a wall from inside with termPIR AL GK: details that matter

What does the EPS code on an insulation board label mean?

The EPS code on the packaging describes the properties of the board in a structured way. It contains information on dimensions, stability and selected mechanical characteristics. However, it does not replace the entire documentation or the insulation design. We explain the most important symbols and show how to distinguish a declared parameter from a general trade name. EPS stands for expanded polystyrene, i.e. the material commonly known as polystyrene. It is made from expanded granules bonded into a board structure. The designation does not in itself determine whether the product is suitable for a façade, a foundation or a floor. Different grades of EPS have different properties. Further data and the declared application are needed for selection. The documentation for boards for the thermal insulation of buildings refers to standard EN 13163.

By |2026-11-16T04:50:56+01:002021-08-15|Technology and applications|Comments Off on What does the EPS code on an insulation board label mean?

XPS on a balcony. Where does it help, and where does it not eliminate the thermal bridge?

A balcony often connects an external slab to a heated building. In such a place, the heat flow depends on the construction of the connection, and not only on the layer laid on top. XPS can be part of a balcony's thermal insulation and help to limit losses. Extruded polystyrene is light, has low water absorption and can be cut precisely. These advantages are useful in tight details. However, they do not mean that any insulation board will eliminate every structural thermal bridge. A reinforced concrete slab passing through the wall can conduct heat to the outside. XPS laid only on its upper surface changes the conditions but leaves other paths for heat flow. The detail is therefore analysed together with the wall, the underside of the balcony and the edges.

By |2026-11-16T04:50:43+01:002021-07-14|Technology and applications|Comments Off on XPS on a balcony. Where does it help, and where does it not eliminate the thermal bridge?

Roof renovation with Utherm Roof LE: parapet height and insulation continuity

When renovating a roof, Utherm Roof LE can help to limit the height of the new insulation. First, however, the condition of the substrate and the free space at the outlets and skylights must be established. Such a survey allows a thickness to be selected that suits the actual renovation conditions. Utherm Roof LE is a PIR board intended for flat roofs and roofs with a low pitch. The core is covered on both sides by a multi-layer, gas-tight laminate. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. The inspection before renovation should cover the limited insulation height at the roof parapet with Utherm Roof LE. During the survey of the existing assembly, the thickness of Roof LE, the slope and the other roof layers must be added together.

By |2026-11-16T00:11:50+01:002021-05-23|Technology and applications|Comments Off on Roof renovation with Utherm Roof LE: parapet height and insulation continuity

Renovating a flat roof with swissporPIR Alu: moisture and drainage

swissporPIR Alu is thermal insulation for flat roofs; its gas-tight facing protects the PIR core and does not replace the covering. The renovation must be based on an assessment of the old substrate, the moisture content of the retained layers and a measurement of the drainage levels after the insulation has been added. Damp boards are not enclosed under a new covering. The fall geometry must be resolved in accordance with the instructions, without accidentally reducing the thickness at the outlet. Below, we explain how the support, the joint layout, the fixing and the drainage relate to the scope of the modernisation. The PIR designation describes the product more precisely than the general terms “polyurethane boards” or “polyurethane foam”; before ordering, the protective layers and the way the new insulation is connected to the retained part of the roof must also be established.

By |2026-11-16T04:50:11+01:002021-04-29|Technology and applications|Comments Off on Renovating a flat roof with swissporPIR Alu: moisture and drainage

Fibre cement fixings and sealing washers: how they work together

The smallest item on the order can determine the tightness of a large roof area. A screw on its own is not yet a complete fixing. Fibre cement sheets require the correct shank, a pressure and sealing component, and a hole made in accordance with the system. Asbestos-free fibre cement should therefore be priced together with the accessories. Replacing them with a random set makes it difficult to predict how the connection will behave under wind and during temperature changes. The shank transfers forces to the substructure. The pressure component distributes the load over the intended area, and the seal limits water ingress. The shape of the head and the way the tool is guided are also important. Damage to one component can weaken the performance of the entire set.

By |2026-11-15T17:20:40+01:002021-04-17|Technology and applications|Comments Off on Fibre cement fixings and sealing washers: how they work together
Back to top